Current heater Harvia Virta Combi
Compare electric heaters

Harvia sauna heater specs

Harvia Virta Combi sauna heater specs and 3D room planner

Use this manual-checked commercial grade Harvia Virta Combi product page to compare the kW range, adjusted room volume, clearances, controller package, rocks, and buying path before you open the sauna in the designer.

Harvia Virta Combi is a floor-standing heater from Harvia for 177-635 cu ft adjusted sauna rooms. Key planning facts: 8-10.8 kW + steam output, 110-154 lbs stone capacity, and 76.2" minimum finished ceiling guidance, and controller guidance: Fenix FX30C, Xenio CX30C / Fenix FX45C, Xenio CX45C.

Design with Harvia Virta Combi Buy in North America at Sauna Marketplace

Power
8-10.8 kW + 2 kW steamer (HL80SA / HL90SA / HL110SA)
Grade
Commercial grade
Rated room volume
177-635 cu ft
Mounting
Floor-standing
Rock capacity
110-154 lb
Dimensions
16.2" W x 16.2" D x 32.9" H / 16.2" W x 19.1" D x 32.9" H
Side/rear clearance
2.01"
Front clearance
2.01"
Top to ceiling clearance
43.3"
Minimum finished ceiling
76.2"
Cold-surface rule
3.94 cu ft per sq ft (1.2 m3 per 1 m2) for glass, stone, tile, brick, concrete, or similar cold surfaces
Controllers
Wi-Fi Enabled Harvia Xenio Combi Controller, Wi-Fi Enabled Harvia Fenix Combi Controller, Fenix FX30C

Quick answers

What is Harvia Virta Combi?

Harvia Virta Combi is a floor-standing heater from Harvia with 8-10.8 kW + steam output and 110-154 lbs stone capacity.

What sauna room size fits Harvia Virta Combi?

The published adjusted room-volume range is 177-635 cu ft. Add glass, tile, stone, brick, concrete, or log exposure before choosing the final kW row.

What clearances does Harvia Virta Combi need?

Plan 2.01" side/back clearance, 2.01" front clearance, and a 76.2" minimum finished ceiling check before placing benches or glass.

Which controller works with Harvia Virta Combi?

Current controller guidance: Fenix FX30C, Xenio CX30C / Fenix FX45C, Xenio CX45C. Match the controller, relay or power unit, and voltage to the selected kW row before ordering.

Where should I start with Harvia Virta Combi?

Use the 3D designer to validate the room, benches, openings, clearances, and material schedule, then use Sauna Marketplace for the current package and buying path.

Harvia Virta Combi size and clearance table

Variant Power Room volume Dimensions Rocks Side/back Front Minimum ceiling Controller
HL80SAHL80SA / US HL8U1SAUL family 8 kW + 2 kW steamer 177-431 cu ft 16.2" W x 16.2" D x 32.9" H 110 lb 2.01" 2.01" 76.2" Fenix FX30C, Xenio CX30C
HL90SAHL90SA / US HL9U1SAUL family 9 kW + 2 kW steamer 283-494 cu ft 16.2" W x 16.2" D x 32.9" H 110 lb 2.01" 2.01" 76.2" Fenix FX30C, Xenio CX30C
HL110SAHL110SA / US HL11U1SAUL family 10.8 kW + 2 kW steamer 318-635 cu ft 16.2" W x 19.1" D x 32.9" H 154 lb 2.01" 2.01" 76.2" Fenix FX45C, Xenio CX45C

Best fit

  • Harvia Virta Combi is flagged as commercial grade for larger residential, spa, or hospitality planning.
  • 8-10.8 kW + steam Harvia heater family for 177-635 cu ft adjusted hot rooms.
  • Floor-standing layouts where the heater footprint, front clearance, and bench approach are planned before ordering.
  • 110-154 lbs stone capacity with Fenix FX30C, Xenio CX30C / Fenix FX45C, Xenio CX45C controller guidance.
  • Rooms that can meet the 76.2" minimum finished ceiling check for the selected size row.
  • Floor space, service access, guard rail planning, and cold-surface sizing should be checked with the full room layout.

Designer checks

  • Size the room by adjusted volume, including the 3.94 cu ft per sq ft (1.2 m3 per 1 m2) for glass, stone, tile, brick, concrete, or similar cold surfaces rule where it applies.
  • Validate side/back clearance 2.01", front clearance 2.01", and bench setback before finalizing benches.
  • Check the 76.2" minimum finished ceiling against the room height.
  • Carry the selected Fenix FX30C, Xenio CX30C / Fenix FX45C, Xenio CX45C package into the material schedule and heater placement notes.

Package notes

  • Harvia Virta Combi auto-fill heater body
  • 110-154 lb; Recommended Stones for Harvia Virta Combi
  • Installation manual
  • Recommended Stones for Harvia Virta Combi
  • Recommended Stones with Decorative White Layer on Top

Manual-backed facts

Source

Harvia Virta Combi installation and use manual

source: Harvia Virta Combi HLS/HLSA installation manual, US Fenix/Xenio Combi control manual, and CAD archive (HLS_HLSA_FISVENDERUETESPL_ZCU-851_090823_web.pdf; Fenix_Xenio_combi_US_04-26_ENFR_Y05-1513.pdf; 4030 and 4028 USA SAT assets rebuilt through Blender; current Harvia US HL80SA, HL90SA, and HL110SA pages checked; checked June 11, 2026)

Mounting

Floor-standing

Floor-standing sizes use their own body height and top clearance.

Model numbers

HL80SA / US HL8U1SAUL family / HL90SA / US HL9U1SAUL family / HL110SA / US HL11U1SAUL family

Useful when the store name and manual model number are not identical.

Room volume range

177-635 cu ft

Use adjusted sauna volume after cold surfaces, not just geometric room volume.

Cold-surface adder

3.94 cu ft per sq ft (1.2 m3 per 1 m2) for glass, stone, tile, brick, concrete, or similar cold surfaces

The calculator applies the brand-family coefficient before selecting a heater size.

Minimum finished ceiling

76.2"

Computed from body height, floor clearance, top clearance, and the manual minimum room height.

Maximum room height

Not listed for these sizes

Verify with the selected manual when designing unusually tall rooms.

Electrical/control

240V 1PH (U1), 208V 3PH (U3); Fenix FX30C, Xenio CX30C / 240V 1PH (U1), 208V 3PH (U3); Fenix FX45C, Xenio CX45C

Use the selected kW row and SKU when matching breakers, phases, relays, and controller packages.

Critical differences

Humidity sensor Cold-water shutoff and vacuum breaker

7 more notes shown below.

  • Humidity sensor
  • Cold-water shutoff and vacuum breaker
  • Floor drain
  • Harvia Virta Combi is listed as commercial grade in SaunaDesignPro.
  • Virta Combi is part of the commercial-grade Harvia Virta set and adds a steamer, humidity sensor, cold-water shutoff/vacuum breaker, and floor drain requirements.
  • Current Harvia US Combi rows list 2 in clearances; the local Virta Combi HL70S-HL110SA safety drawing also lists 30 mm around the heater and 1100 mm above the stones to the ceiling, so use the stricter listing/AHJ value where values conflict.
  • Combi sensor placement follows the same sheet logic as standard Virta: a wall sensor above the heater 30-150 mm below the ceiling, moving to a ceiling-mounted sensor 100 mm out when the heater sits more than 150 mm from the wall.
  • The Combi evaporator adds a 2.0 kW steamer rated at roughly 2.5 kg/h with a 5 L water reservoir: fill with clean household water before use, drain after every use, and follow the manual water-quality table; SA models support automatic filling.
  • Combi HL80SA/HL90SA rows use 110 lb stones and HL110SA uses 154 lb; heating elements are separated from the stones and the stones should be rearranged during regular maintenance.

More heater pages