Current heater Harvia KIP
Compare electric heaters

Harvia sauna heater specs

Harvia KIP sauna heater specs and 3D room planner

Use this manual-checked Harvia KIP product page to compare the kW range, adjusted room volume, clearances, controller package, rocks, and buying path before you open the sauna in the designer.

Harvia KIP is a wall-mounted heater from Harvia for 100-425 cu ft adjusted sauna rooms. Key planning facts: 4.5-8 kW output, 50 lbs stone capacity, and 75" minimum finished ceiling guidance, and controller guidance: Built-in controls or Harvia Xenio wall control, by model.

Design with Harvia KIP Buy in North America at Sauna Marketplace

Power
4.5-8 kW
Rated room volume
100-425 cu ft
Mounting
Wall-mounted
Rock capacity
50 lb
Dimensions
16.3" W x 10.9" D x 23.4" H
Side/rear clearance
3.00"-5.00"
Front clearance
4.00"-6.00"
Top to ceiling clearance
43.5"
Minimum finished ceiling
75"
Cold-surface rule
3.94 cu ft per sq ft (1.2 m3 per 1 m2) for glass, stone, tile, brick, concrete, or similar cold surfaces
Controllers
KIP-W + Wi-Fi Enabled Harvia Xenio CX170, KIP-B Built-In Controls, Built-in controls or Harvia Xenio wall control, by model

Quick answers

What is Harvia KIP?

Harvia KIP is a wall-mounted heater from Harvia with 4.5-8 kW output and 50 lbs stone capacity.

What sauna room size fits Harvia KIP?

The published adjusted room-volume range is 100-425 cu ft. Add glass, tile, stone, brick, concrete, or log exposure before choosing the final kW row.

What clearances does Harvia KIP need?

Plan 3.00"-5.00" side/back clearance, 4.00"-6.00" front clearance, and a 75" minimum finished ceiling check before placing benches or glass.

Which controller works with Harvia KIP?

Current controller guidance: Built-in controls or Harvia Xenio wall control, by model. Match the controller, relay or power unit, and voltage to the selected kW row before ordering.

Where should I start with Harvia KIP?

Use the 3D designer to validate the room, benches, openings, clearances, and material schedule, then use Sauna Marketplace for the current package and buying path.

Harvia KIP size and clearance table

Variant Power Room volume Dimensions Rocks Side/back Front Minimum ceiling Controller
4.5 kW4.5 kW 4.5 kW 100-210 cu ft 16.3" W x 10.9" D x 23.4" H 50 lb 3.00" 4.00" 75" Built-in controls or Harvia Xenio wall control, by model
6 kW6 kW 6 kW 170-300 cu ft 16.3" W x 10.9" D x 23.4" H 50 lb 4.00" 4.75" 75" Built-in controls or Harvia Xenio wall control, by model
8 kW8 kW 8 kW 250-425 cu ft 16.3" W x 10.9" D x 23.4" H 50 lb 5.00" 6.00" 75" Built-in controls or Harvia Xenio wall control, by model

Best fit

  • 4.5-8 kW Harvia heater family for 100-425 cu ft adjusted hot rooms.
  • Wall-mounted layouts where the heater footprint, front clearance, and bench approach are planned before ordering.
  • 50 lbs stone capacity with Built-in controls or Harvia Xenio wall control, by model controller guidance.
  • Rooms that can meet the 75" minimum finished ceiling check for the selected size row.
  • Wall blocking, cladding buildup, and heater bottom height should be resolved before paneling goes in.

Designer checks

  • Size the room by adjusted volume, including the 3.94 cu ft per sq ft (1.2 m3 per 1 m2) for glass, stone, tile, brick, concrete, or similar cold surfaces rule where it applies.
  • Validate side/back clearance 3.00"-5.00", front clearance 4.00"-6.00", and bench setback before finalizing benches.
  • Check the 75" minimum finished ceiling against the room height.
  • Carry the selected Built-in controls or Harvia Xenio wall control, by model package into the material schedule and heater placement notes.

Package notes

  • Harvia KIP wall-mounted heater body
  • 50 lb; 50 lb Sauna Stones for Harvia KIP
  • External temperature sensor for KIP-W controller models
  • 50 lb Sauna Stones for Harvia KIP
  • Harvia White Rocks Upgrade

Manual-backed facts

Source

Harvia KIP installation and use manual

source: Harvia KIP Owner’s/Operator’s Manual (KIP-B/W US/Canada manual 02052023/Y05-0623; checked May 18, 2026)

Mounting

Wall-mounted

Floor clearance shows the minimum bottom height where the manual lists one.

Model numbers

4.5 kW / 6 kW / 8 kW

Useful when the store name and manual model number are not identical.

Room volume range

100-425 cu ft

Use adjusted sauna volume after cold surfaces, not just geometric room volume.

Cold-surface adder

3.94 cu ft per sq ft (1.2 m3 per 1 m2) for glass, stone, tile, brick, concrete, or similar cold surfaces

The calculator applies the brand-family coefficient before selecting a heater size.

Minimum finished ceiling

75"

Computed from body height, floor clearance, top clearance, and the manual minimum room height.

Maximum room height

96"

Sizes with a maximum ceiling should not be stretched beyond this value without manufacturer review.

Electrical/control

240V 1PH; some sizes available 208V 3PH; Built-in controls or Harvia Xenio wall control, by model

Use the selected kW row and SKU when matching breakers, phases, relays, and controller packages.

Critical differences

KIP US minimum room height is 75 in, Canada is 78 in, and the manual lists 96 in as the normal maximum sauna height.

  • KIP US minimum room height is 75 in, Canada is 78 in, and the manual lists 96 in as the normal maximum sauna height.