What is HUUM CLIFF?
HUUM CLIFF is a floor-standing heater from HUUM with 6-11 kW output and 165 lbs stone capacity.
HUUM sauna heater specs
Use this manual-checked HUUM CLIFF product page to compare US and EU power options, adjusted room volume, clearances, UKU controls, rocks, and the shared HUUM 3D body before choosing the correct regional electrical package.
HUUM CLIFF is a floor-standing heater from HUUM for 177-566 cu ft adjusted sauna rooms. Key planning facts: 6-11 kW output, 165 lbs stone capacity, and 86.6" minimum finished ceiling guidance, controller guidance: HUUM UKU certified controls, and separate US 240/208V 2~; EU 230V 1/N~ or 400V 3/N~ regional electrical rows that share the 3D body only for layout planning.
Design with HUUM CLIFF Buy in North America at Sauna Marketplace
HUUM CLIFF is a floor-standing heater from HUUM with 6-11 kW output and 165 lbs stone capacity.
The published adjusted room-volume range is 177-566 cu ft. Add glass, tile, stone, brick, concrete, or log exposure before choosing the final kW row.
Plan 2.36"-15" side/back clearance, 15.3"-40.5" front clearance, and a 86.6" minimum finished ceiling check before placing benches or glass.
Current controller guidance: HUUM UKU certified controls. Match the controller, relay or power unit, and voltage to the selected kW row before ordering.
HUUM CLIFF uses the same 3D heater body/envelope in SaunaDesignPro for US and EU planning, but the electrical SKUs are separate. Mini 4 uses an EU 230V 1/N~ row; full-size 6, 9, and 11 rows show EU 230V 1/N~ or 400V 3/N~ wiring. The EU 11 rows are 10.5 kW while the US rows list 11 kW. Match the final phase, voltage, breaker, cable, controller, listing, and warranty to the regional manual before ordering.
Use the 3D designer to validate the room, benches, openings, clearances, and material schedule, then use Sauna Marketplace for the current package and buying path.
| Variant | Power | Room volume | Dimensions | Rocks | Side/back | Front | Minimum ceiling | Controller |
|---|---|---|---|---|---|---|---|---|
| CLIFF 6CLIFF 6 | 6 kW | 177-318 cu ft | 10.6" W x 10.6" D x 38.4" H | 165 lb | 2.36" | 15.3" | 86.6" | HUUM UKU certified controls |
| CLIFF 9CLIFF 9 | 9 kW | 283-460 cu ft | 10.6" W x 10.6" D x 38.4" H | 165 lb | 9.45" | 29.5" | 86.6" | HUUM UKU certified controls |
| CLIFF 11CLIFF 11 | 11 kW | 354-566 cu ft | 10.6" W x 10.6" D x 38.4" H | 165 lb | 15" | 40.5" | 86.6" | HUUM UKU certified controls |
HUUM CLIFF US installation and operation manual
source: HUUM CLIFF and CLIFF Mini Installation and Operation Manual (H1004L03 v9 US manual; PDF saved from HUUM public design resources; checked May 23, 2026)
Floor-standing
Floor-standing sizes use their own body height and top clearance.
CLIFF 6 / CLIFF 9 / CLIFF 11
Useful when the store name and manual model number are not identical.
177-566 cu ft
Use adjusted sauna volume after cold surfaces, not just geometric room volume.
3.3 cu ft per sq ft (1 m3 per 1 m2) for uninsulated brick, tile, glass, or similar surfaces
The calculator applies the brand-family coefficient before selecting a heater size.
86.6"
Computed from body height, floor clearance, top clearance, and the manual minimum room height.
Not listed for these sizes
Verify with the selected manual when designing unusually tall rooms.
US: 6 kW at 240V 2~; 208V 2~ derates to 4.8 kW, EU: 6 kW at 230V 1/N~ or 400V 3/N~ (3 x 10A at 400V); HUUM UKU certified controls / US: 9 kW at 240V 2~; 208V 2~ derates to 7.1 kW, EU: 9 kW at 230V 1/N~ or 400V 3/N~ (3 x 16A at 400V); HUUM UKU certified controls / +1 more
Use the selected kW row and SKU when matching breakers, phases, relays, and controller packages.
Certified control system required Add glass/tile/brick penalty before sizing
8 more notes shown below.
US 240/208V 2~; EU 230V 1/N~ or 400V 3/N~
Mini 4 uses an EU 230V 1/N~ row; full-size 6, 9, and 11 rows show EU 230V 1/N~ or 400V 3/N~ wiring. The EU 11 rows are 10.5 kW while the US rows list 11 kW.
Shared HUUM body/envelope for US and EU planning
HUUM CLIFF US and EU rows use the same SaunaDesignPro 3D body/envelope for placement. Do not treat that as the same electrical SKU; use the selected regional manual for output, phase, breaker, cable, controller, listing, and warranty.