Harvia Pro Wood sauna heater specs and 3D room planner
Use this catalog-backed Harvia Pro Wood product page to compare wood output, adjusted room volume, clearances, chimney path, stones, floor protection, and manual install checks before you open the sauna in the designer.
Harvia Pro Wood is a floor-standing heater from Harvia for 283-1271 cu ft adjusted sauna rooms. Key planning facts: 24.1-31 kW output, 88-132 lbs stone capacity, and 91" minimum finished ceiling guidance, plus wood-stove chimney path, manual flue connection, hearth/floor protection, combustion air, and local fire-code review.
16.9" W x 20.1" D x 29.9" H / 16.9" W x 28.4" D x 29.9" H
Side/rear clearance
11.8"-19.7"
Front clearance
11.8"-19.7"
Top to ceiling clearance
49.2"-51.2"
Minimum finished ceiling
91"
Cold-surface rule
3.94 cu ft per sq ft (1.2 m3 per 1 m2) for glass, stone, tile, brick, concrete, or similar cold surfaces
Chimney / install package
Manual wood stove; chimney and hearth package by installer, Wood stove chimney and hearth package by installer
Quick answers
What is Harvia Pro Wood?
Harvia Pro Wood is a floor-standing heater from Harvia with 24.1-31 kW output and 88-132 lbs stone capacity.
What sauna room size fits Harvia Pro Wood?
The published adjusted room-volume range is 283-1271 cu ft. Add glass, tile, stone, brick, concrete, or log exposure before choosing the final kW row.
What clearances does Harvia Pro Wood need?
Plan 11.8"-19.7" side/back clearance, 11.8"-19.7" front clearance, and a 91" minimum finished ceiling check before placing benches or glass.
What chimney does Harvia Pro Wood need?
Plan a manual-approved chimney path with the manual-listed stove connection, the selected WHP chimney parts or AHJ-approved equivalent, lead-through protection, and local fire-code review.
Where should I start with Harvia Pro Wood?
Use the 3D designer to validate the room, benches, openings, combustible clearances, chimney lead-through, guard rail, hearth protection, and material schedule before purchase.
Harvia Pro Wood size and clearance table
Variant
Power
Room volume
Dimensions
Rocks
Side/back
Front
Minimum ceiling
Chimney / install
Pro 20WKPR20M
24.1 kW
283-706 cu ft
16.9" W x 20.1" D x 29.9" H
88.2 lb
11.8"
11.8"
91"
Manual wood stove; chimney and hearth package by installer
Pro 20 SLWKPR20SLM
24.1 kW
283-706 cu ft
16.9" W x 28.4" D x 29.9" H
88.2 lb
11.8"
11.8"
91"
Manual wood stove; chimney and hearth package by installer
Pro 20 ESWKPR20ESM
24.1 kW
283-706 cu ft
16.9" W x 25.6" D x 29.9" H
88.2 lb
11.8"
11.8"
91"
Manual wood stove; chimney and hearth package by installer
Pro 20 RSWKPR20RSM
24.1 kW
283-706 cu ft
22.8" W x 20.1" D x 29.9" H
88.2 lb
11.8"
11.8"
91"
Manual wood stove; chimney and hearth package by installer
Pro 20 LSWKPR20LSM
24.1 kW
283-706 cu ft
22.8" W x 20.1" D x 29.9" H
88.2 lb
11.8"
11.8"
91"
Manual wood stove; chimney and hearth package by installer
Pro 20 DuoWKPR20DUOS
24.1 kW
283-706 cu ft
16.9" W x 31.1" D x 29.9" H
88.2 lb
11.8"
11.8"
91"
Manual wood stove; chimney and hearth package by installer
Pro 26WKPR26M
26.6 kW
353-918 cu ft
16.9" W x 20.1" D x 31.9" H
110.3 lb
14.8"
14.8"
91"
Manual wood stove; chimney and hearth package by installer
Pro 36WKPR36M
31 kW
494-1271 cu ft
20.1" W x 20.1" D x 31.9" H
132.3 lb
19.7"
19.7"
91"
Manual wood stove; chimney and hearth package by installer
Pro 36 DuoWKPR36DUOS
31 kW
494-1271 cu ft
20.1" W x 31.1" D x 40.9" H
132.3 lb
19.7"
19.7"
91"
Manual wood stove; chimney and hearth package by installer
Best fit
24.1-31 kW Harvia heater family for 283-1271 cu ft adjusted hot rooms.
Floor-standing layouts where the heater footprint, front clearance, and bench approach are planned before ordering.
88-132 lbs stone capacity with chimney, hearth, heat-shield, and combustion-air planning handled before ordering.
Rooms that can meet the 91" minimum finished ceiling check for the selected size row.
Floor structure, non-combustible base, stove guard rail, chimney route, and roof lead-through should be resolved with the full room layout.
Designer checks
Size the room by adjusted volume, including the 3.94 cu ft per sq ft (1.2 m3 per 1 m2) for glass, stone, tile, brick, concrete, or similar cold surfaces rule where it applies.
Validate side/back clearance 11.8"-19.7", front clearance 11.8"-19.7", and bench setback before finalizing benches.
Check the 91" minimum finished ceiling against the room height.
Carry chimney kit/extensions/damper, lead-through, hearth protection, heat shields, ash handling, and local fire-code review into the material schedule.
Package notes
Selected Harvia Pro wood stove body with glass fire door
88-132 lb; Harvia Pro Sauna Stones
Installation and operation manual
Harvia Pro Sauna Stones
Harvia Stainless Steel Chimney Kit for Flat Roof
Manual-backed facts
Source
SaunaDesignPro heater catalog
Confirm the source file before ordering.
Mounting
Floor-standing
Floor-standing sizes use their own body height and top clearance.
Model numbers
WKPR20M / WKPR20SLM / WKPR20ESM / WKPR20RSM / +5 more
Useful when the store name and manual model number are not identical.
Room volume range
283-1271 cu ft
Use adjusted sauna volume after cold surfaces, not just geometric room volume.
Body weight
116.9-187.4 lb
Listed body weight before stones; verify shipping weight with the final SKU.
Cold-surface adder
3.94 cu ft per sq ft (1.2 m3 per 1 m2) for glass, stone, tile, brick, concrete, or similar cold surfaces
The calculator applies the brand-family coefficient before selecting a heater size.
Minimum finished ceiling
91"
Computed from body height, floor clearance, top clearance, and the manual minimum room height.
Maximum room height
Not listed for these sizes
Verify with the selected manual when designing unusually tall rooms.
Electrical/control
Wood-burning; no electric heater circuit; Manual wood stove; chimney and hearth package by installer
Use the selected kW row and SKU when matching breakers, phases, relays, and controller packages.
Critical differences
Harvia Pro high-output wood stove for large and commercial rooms; T600 chimney, 115 mm connection / 110 mm min flue inner diameter, top or rear exit For US 6" Class-A chimney, Harvia sells the WZ115155 4.5"->6" adapter
10 more notes shown below.
Harvia Pro high-output wood stove for large and commercial rooms; T600 chimney, 115 mm connection / 110 mm min flue inner diameter, top or rear exit
For US 6" Class-A chimney, Harvia sells the WZ115155 4.5"->6" adapter
Clearances shown are to combustible material without a shield; a Harvia WL protective sheath reduces side/rear substantially (see product page)
Load 10-15 cm stones loosely with airflow open; the manual safety distances assume the stones are installed correctly and no wiring or combustibles enter the clearance envelope
Harvia WHP insulated chimney is T600/G100: keep 100 mm from its outer casing to combustibles; uninsulated smoke pipe needs 500 mm unless an approved Harvia radiation cover or protective system is specified
Use a manufacturer-approved non-combustible hearth/protective bedding over wood or tiled waterproofed floors; roof-ceiling lead-through, combustion air, support spacing, termination, and local fire-code review are required
Manual 4618 Fig 7: ceiling 1300, side/back/front 300 mm. WL500/WL550 sheath cuts side/back to 62 mm.
SL feeds through the wall: opening min 405 W x 485 H from floor, wall max 120 mm thick, feed protrudes max 150 mm (manual 4922 Fig 11). Shares Pro 20 clearances.
ES = external feed with a 20 L water tank; shares the Pro 20 body clearances. Confirm final body dimensions against Harvia CAD before quoting.
RS = right-side feed with a 30 L water tank; shares the Pro 20 body clearances. WL500/WL590 sheath. Mirror model Pro 20 LS (WKPR20LSM).
LS = left-side feed with a 30 L water tank; mirror of Pro 20 RS. Shares the Pro 20 body clearances. WL500/WL590 sheath.
Duo = see-through fireplace + sauna stove combo through the wall, pairs with the Harvia Duo glass wall; 100 mm min from combustible structure to the chimney (manual 4922).