Current heater Harvia Linear Wood
Compare wood stoves

Harvia sauna heater specs

Harvia Linear Wood sauna heater specs and 3D room planner

Use this catalog-backed Harvia Linear Wood product page to compare wood output, adjusted room volume, clearances, chimney path, stones, floor protection, and manual install checks before you open the sauna in the designer.

Harvia Linear Wood is a floor-standing heater from Harvia for 177-636 cu ft adjusted sauna rooms. Key planning facts: 14.3-17.9 kW output, 79-88 lbs stone capacity, and 82" minimum finished ceiling guidance, plus T600 chimney path, 115 mm flue connection, hearth/floor protection, combustion air, and local fire-code review.

Design with Harvia Linear Wood Buy in North America at Sauna Marketplace

Power
14.3-17.9 kW wood
Rated room volume
177-636 cu ft
Mounting
Floor-standing
Rock capacity
80-88 lb
Dimensions
16.5" W x 17.7" D x 28.9" H / 17.7" W x 20.1" D x 30.3" H
Side/rear clearance
side 3.62"-15.8" / rear 3.62"-15"
Front clearance
11.8"-19.7"
Top to ceiling clearance
49.8"-51.2"
Minimum finished ceiling
82"
Cold-surface rule
3.94 cu ft per sq ft (1.2 m3 per 1 m2) for glass, stone, tile, brick, concrete, or similar cold surfaces
Chimney / install package
Manual wood stove; chimney and hearth package by installer, Wood stove chimney and hearth package by installer

Quick answers

What is Harvia Linear Wood?

Harvia Linear Wood is a floor-standing heater from Harvia with 14.3-17.9 kW output and 79-88 lbs stone capacity.

What sauna room size fits Harvia Linear Wood?

The published adjusted room-volume range is 177-636 cu ft. Add glass, tile, stone, brick, concrete, or log exposure before choosing the final kW row.

What clearances does Harvia Linear Wood need?

Plan 3.62"-15.8" side clearance, 3.62"-15" rear clearance, 11.8"-19.7" front clearance, and a 82" minimum finished ceiling check before placing benches or glass.

What chimney does Harvia Linear Wood need?

Plan a T600 chimney path with 115 mm stove connection, the selected WHP chimney parts or AHJ-approved equivalent, lead-through protection, and local fire-code review.

Where should I start with Harvia Linear Wood?

Use the 3D designer to validate the room, benches, openings, combustible clearances, chimney lead-through, guard rail, hearth protection, and material schedule before purchase.

Harvia Linear Wood size and clearance table

Variant Power Room volume Dimensions Rocks Side/back Front Minimum ceiling Chimney / install
Linear 16WKP160C 17.9 kW 212-565 cu ft 16.5" W x 17.7" D x 28.9" H 80 lb 11.8" 15.8" 82" Manual wood stove; chimney and hearth package by installer
Linear 18 CompactWKLI18CPTM 14.3 kW 177-636 cu ft 17.7" W x 20.1" D x 30.3" H 88.2 lb 3.62" 11.8" 82" Manual wood stove; chimney and hearth package by installer
Linear 22 GreenFlameWKLI20GM 15.7 kW 318-636 cu ft 17.7" W x 20.1" D x 30.3" H 88.2 lb 15.8" 19.7" 82" Manual wood stove; chimney and hearth package by installer
Linear 22 GreenFlame ESWKLI20GESM 15.7 kW 318-636 cu ft 17.7" W x 26" D x 30.3" H 88.2 lb 15.8" 19.7" 82" Manual wood stove; chimney and hearth package by installer

Best fit

  • 14.3-17.9 kW Harvia heater family for 177-636 cu ft adjusted hot rooms.
  • Floor-standing layouts where the heater footprint, front clearance, and bench approach are planned before ordering.
  • 79-88 lbs stone capacity with chimney, hearth, heat-shield, and combustion-air planning handled before ordering.
  • Rooms that can meet the 82" minimum finished ceiling check for the selected size row.
  • Floor structure, non-combustible base, stove guard rail, chimney route, and roof lead-through should be resolved with the full room layout.

Designer checks

  • Size the room by adjusted volume, including the 3.94 cu ft per sq ft (1.2 m3 per 1 m2) for glass, stone, tile, brick, concrete, or similar cold surfaces rule where it applies.
  • Validate side/back clearance 3.62"-15.8", front clearance 11.8"-19.7", and bench setback before finalizing benches.
  • Check the 82" minimum finished ceiling against the room height.
  • Carry chimney kit/extensions/damper, lead-through, hearth protection, heat shields, ash handling, and local fire-code review into the material schedule.

Package notes

  • Selected Harvia Linear wood stove body with glass fire door
  • 80-88 lb; Harvia Linear Sauna Stones
  • Installation and operation manual
  • Harvia Linear Sauna Stones
  • Harvia WHP1500M Black Chimney Kit

Manual-backed facts

Source

SaunaDesignPro heater catalog

Confirm the source file before ordering.

Mounting

Floor-standing

Floor-standing sizes use their own body height and top clearance.

Model numbers

WKP160C / WKLI18CPTM / WKLI20GM / WKLI20GESM

Useful when the store name and manual model number are not identical.

Room volume range

177-636 cu ft

Use adjusted sauna volume after cold surfaces, not just geometric room volume.

Body weight

101.4-167.6 lb

Listed body weight before stones; verify shipping weight with the final SKU.

Cold-surface adder

3.94 cu ft per sq ft (1.2 m3 per 1 m2) for glass, stone, tile, brick, concrete, or similar cold surfaces

The calculator applies the brand-family coefficient before selecting a heater size.

Minimum finished ceiling

82"

Computed from body height, floor clearance, top clearance, and the manual minimum room height.

Maximum room height

Not listed for these sizes

Verify with the selected manual when designing unusually tall rooms.

Electrical/control

Wood-burning; no electric heater circuit; Manual wood stove; chimney and hearth package by installer

Use the selected kW row and SKU when matching breakers, phases, relays, and controller packages.

Critical differences

Harvia Linear clean-burn wood stove; T600 chimney, 115 mm connection / 110 mm min flue inner diameter, top or rear exit For a US 6" Class-A chimney, SaunaMarketplace stocks the WZ115155 4.5"->6" adapter; the assembled hybrid stack is an installer/AHJ-specified system - Harvia's own WHP chimney documentation covers vertical roof-pass installs only

10 more notes shown below.

Fuel / standard

Wood

Flue class / diameter

T600; 115 mm connection; 110 mm min pipe ID

Connection locations: Verify.

WHP chimney clearance

100 mm insulated chimney to combustibles; 500 mm single-wall pipe to walls (stainless; 375 mm with the black WHP1500M connector)

The insulated chimney runs 220 mm outside diameter over the 115 mm smoke pipe. Keep at least 430 mm of insulated chimney visible in the room. Lead-through insulation must be class A or long-term rated at 750 C or more (Harvia ZSH-200 in the kit).

WHP chimney scope

Vertical roof-pass installs only; standalone outdoor sauna buildings per Harvia support (2026)

For an indoor or residential build, the installer specifies a listed North American chimney path (e.g. UL 103 HT Class A via a 115 mm to 6" adapter) with AHJ sign-off instead of the WHP kit. Harvia 115 mm smoke pipes and WHP chimneys fit all Harvia wood-heated sauna stoves except the Harvia 50, plus the Harvia 10 iron stove.

WHP chimney limits

5 m max chimney elements; 2 m max freestanding element; 3 m max indoor lateral-support spacing

  • Harvia Linear clean-burn wood stove; T600 chimney, 115 mm connection / 110 mm min flue inner diameter, top or rear exit
  • For a US 6" Class-A chimney, SaunaMarketplace stocks the WZ115155 4.5"->6" adapter; the assembled hybrid stack is an installer/AHJ-specified system - Harvia's own WHP chimney documentation covers vertical roof-pass installs only
  • Harvia support (2026) specifies the WHP steel chimney for standalone outdoor sauna buildings; indoor or residential builds need an installer-specified listed chimney path (e.g. UL 103 HT Class A)
  • Clearances shown are to combustible material without a shield; a Harvia WL protective sheath reduces side/rear substantially (see product page)
  • Load 10-15 cm stones loosely with airflow open; the manual safety distances assume the stones are installed correctly and no wiring or combustibles enter the clearance envelope
  • Harvia WHP insulated chimney is T600/G100: keep 100 mm from its outer casing to combustibles; the uninsulated smoke pipe needs 500 mm (stainless) or 375 mm (black WHP1500M connector) unless an approved Harvia radiation cover or protective system is specified
  • Use a manufacturer-approved non-combustible hearth/protective bedding over wood or tiled waterproofed floors; roof-ceiling lead-through, combustion air, support spacing, termination, and local fire-code review are required
  • Manual 301-Pk safety Fig 7: side 300, back 350, front 400, ceiling 1300 mm. WL425/WL475 sheath cuts side/back to 30 mm.
  • Double-shell design: installs just 92 mm from combustible side/rear walls with NO protective sheath (manual 3669 Fig 5). A non-combustible ceiling shield drops the ceiling clearance from 1300 to 1050 mm.
  • Not currently on SaunaMarketplace; sourced via Harvia US (BathingBrands).
  • Manual 4897 Fig 9: ceiling 1265, side 400, back 380, front 500 mm. WL525/WL575 sheath cuts side/back to 70 mm.
  • ES = a fixed 20 L water tank on the FRONT of the stove, not an external/through-wall feed (RS/LS are the same tank on the right/left); shares the Linear 22 GreenFlame safety envelope. WL530/WL580 sheath cuts side/back to 70 mm.