Current heater Harvia Legend Wood
Compare wood stoves

Harvia sauna heater specs

Harvia Legend Wood sauna heater specs and 3D room planner

Use this manual-checked Harvia Legend Wood product page to compare wood output, adjusted room volume, clearances, chimney path, stones, floor protection, and manual install checks before you open the sauna in the designer.

Harvia Legend Wood is a floor-standing heater from Harvia for 212-1059 cu ft adjusted sauna rooms. Key planning facts: 15.9-23.5 kW output, 265-573 lbs stone capacity, and 75"-81" minimum finished ceiling guidance, plus T600 chimney path, 115 mm flue connection, hearth/floor protection, combustion air, and local fire-code review.

Design with Harvia Legend Wood Buy in North America at Sauna Marketplace

Power
15.9-23.5 kW wood
Rated room volume
212-1059 cu ft
Mounting
Floor-standing
Rock capacity
264-573 lb
Dimensions
20.9" W x 20.9" D x 29.1" H / 23.6" W x 23.6" D x 32.7" H
Side/rear clearance
side 7.87" / rear 9.84"
Front clearance
19.7"-27.6"
Top to ceiling clearance
39.4"-47.2"
Minimum finished ceiling
75"-81"
Cold-surface rule
3.94 cu ft per sq ft (1.2 m3 per 1 m2) for glass, stone, tile, brick, concrete, or similar cold surfaces
Chimney / install package
Manual wood stove; chimney and hearth package by installer, Wood stove chimney and hearth package by installer

Quick answers

What is Harvia Legend Wood?

Harvia Legend Wood is a floor-standing heater from Harvia with 15.9-23.5 kW output and 265-573 lbs stone capacity.

What sauna room size fits Harvia Legend Wood?

The published adjusted room-volume range is 212-1059 cu ft. Add glass, tile, stone, brick, concrete, or log exposure before choosing the final kW row.

What clearances does Harvia Legend Wood need?

Plan 7.87" side clearance, 9.84" rear clearance, 19.7"-27.6" front clearance, and a 75"-81" minimum finished ceiling check before placing benches or glass.

What chimney does Harvia Legend Wood need?

Plan a T600 chimney path with 115 mm stove connection, the selected WHP chimney parts or AHJ-approved equivalent, lead-through protection, and local fire-code review.

Where should I start with Harvia Legend Wood?

Use the 3D designer to validate the room, benches, openings, combustible clearances, chimney lead-through, guard rail, hearth protection, and material schedule before purchase.

Harvia Legend Wood size and clearance table

Variant Power Room volume Dimensions Rocks Side/back Front Minimum ceiling Chimney / install
Legend 150WK150LD 16 kW 212-459 cu ft 20.9" W x 20.9" D x 29.1" H 264 lb 7.87" 19.7" 78.7" Manual wood stove; chimney and hearth package by installer
Legend 240WK240LD 21 kW 353-706 cu ft 23.6" W x 23.6" D x 32.7" H 440 lb 7.87" 24.8" 80.1" Manual wood stove; chimney and hearth package by installer
Legend 150 SLWK150LDSL 16 kW 212-459 cu ft 20.9" W x 28.7" D x 29.1" H 264 lb 7.87" 19.7" 78.7" Manual wood stove; chimney and hearth package by installer
Legend 240 GreenFlameWKLE20GM 15.9 kW 353-706 cu ft 23.6" W x 23.6" D x 32.9" H 440 lb 7.87" 24.8" 80.1" Manual wood stove; chimney and hearth package by installer
Legend 300WK300LD 23 kW 494-989 cu ft 23.6" W x 26" D x 40.9" H 573.2 lb 7.87" 26.8" 81" Manual wood stove; chimney and hearth package by installer
Legend 240 SLWKLE20SLM 21 kW 353-847 cu ft 23.6" W x 30.7" D x 32.7" H 440.9 lb 7.87" 24.8" 75" Manual wood stove; chimney and hearth package by installer
Legend 240 DuoWKLE20DUOM / WKLE20DUOMM 21 kW 353-847 cu ft 23.6" W x 30.7" D x 32.7" H 440.9 lb 7.87" 24.8" 75" Manual wood stove; chimney and hearth package by installer
Legend 300 DuoWKLE36DUOM / WKLE36DUOMM 23.5 kW 530-1059 cu ft 23.6" W x 30.7" D x 40.9" H 573.2 lb 7.87" 27.6" 81" Manual wood stove; chimney and hearth package by installer

Best fit

  • 15.9-23.5 kW Harvia heater family for 212-1059 cu ft adjusted hot rooms.
  • Floor-standing layouts where the heater footprint, front clearance, and bench approach are planned before ordering.
  • 265-573 lbs stone capacity with chimney, hearth, heat-shield, and combustion-air planning handled before ordering.
  • Rooms that can meet the 75"-81" minimum finished ceiling check for the selected size row.
  • Floor structure, non-combustible base, stove guard rail, chimney route, and roof lead-through should be resolved with the full room layout.

Designer checks

  • Size the room by adjusted volume, including the 3.94 cu ft per sq ft (1.2 m3 per 1 m2) for glass, stone, tile, brick, concrete, or similar cold surfaces rule where it applies.
  • Validate side/back clearance 7.87", front clearance 19.7"-27.6", and bench setback before finalizing benches.
  • Check the 75"-81" minimum finished ceiling against the room height.
  • Carry chimney kit/extensions/damper, lead-through, hearth protection, heat shields, ash handling, and local fire-code review into the material schedule.

Package notes

  • Selected Harvia Legend wood stove body
  • 264-573 lb; Harvia Legend Sauna Stones
  • Installation and operation manual
  • Harvia Legend Sauna Stones
  • Harvia WHP1500 Stainless Steel Chimney Kit

Manual-backed facts

Source

Harvia Legend wood stove manuals and WHP steel chimney references

source: Harvia Legend wood-burning stove manuals and CAD archive (Legend 150/240/300 manual Y05-0136 09/25; Legend 240 SL/Duo and 300 Duo manual Y05-1391 24.10.2024; SAT-derived protected GLBs; checked May 27, 2026)

Mounting

Floor-standing

Floor-standing sizes use their own body height and top clearance.

Model numbers

WK150LD / WK240LD / WK150LDSL / WKLE20GM / +4 more

Useful when the store name and manual model number are not identical.

Room volume range

212-1059 cu ft

Use adjusted sauna volume after cold surfaces, not just geometric room volume.

Body weight

127.9-218.3 lb

Listed body weight before stones; verify shipping weight with the final SKU.

Cold-surface adder

3.94 cu ft per sq ft (1.2 m3 per 1 m2) for glass, stone, tile, brick, concrete, or similar cold surfaces

The calculator applies the brand-family coefficient before selecting a heater size.

Minimum finished ceiling

75"-81"

Computed from body height, floor clearance, top clearance, and the manual minimum room height.

Maximum room height

Not listed for these sizes

Verify with the selected manual when designing unusually tall rooms.

Electrical/control

Wood-burning; no electric heater circuit; Manual wood stove; chimney and hearth package by installer

Use the selected kW row and SKU when matching breakers, phases, relays, and controller packages.

Critical differences

Go-to wood stove family for SaunaDesignPro wood-burning sauna plans T600 chimney required; Harvia manuals list 115 mm connection opening and 110 mm minimum flue inner diameter

10 more notes shown below.

Fuel / standard

Wood

Flue class / diameter

T600; 115 mm connection; 110 mm min pipe ID

Connection locations: Verify.

WHP chimney clearance

100 mm insulated chimney to combustibles; 500 mm single-wall pipe to walls (stainless; 375 mm with the black WHP1500M connector)

The insulated chimney runs 220 mm outside diameter over the 115 mm smoke pipe. Keep at least 430 mm of insulated chimney visible in the room. Lead-through insulation must be class A or long-term rated at 750 C or more (Harvia ZSH-200 in the kit).

WHP chimney scope

Vertical roof-pass installs only; standalone outdoor sauna buildings per Harvia support (2026)

For an indoor or residential build, the installer specifies a listed North American chimney path (e.g. UL 103 HT Class A via a 115 mm to 6" adapter) with AHJ sign-off instead of the WHP kit. Harvia 115 mm smoke pipes and WHP chimneys fit all Harvia wood-heated sauna stoves except the Harvia 50, plus the Harvia 10 iron stove.

WHP chimney limits

5 m max chimney elements; 2 m max freestanding element; 3 m max indoor lateral-support spacing

  • Go-to wood stove family for SaunaDesignPro wood-burning sauna plans
  • T600 chimney required; Harvia manuals list 115 mm connection opening and 110 mm minimum flue inner diameter
  • Use Harvia WHP steel chimney kit/extensions/damper or an AHJ-approved equivalent specified by the installer
  • Harvia WHP steel chimney installs vertically through the roof only, and Harvia support (2026) specifies it for standalone outdoor sauna buildings - indoor or residential builds need an installer-specified listed chimney path (e.g. UL 103 HT Class A)
  • Harvia WHP steel chimney manual lists 100 mm minimum clearance from combustibles to the insulated outer casing; the non-insulated connecting pipe needs 500 mm (stainless WHP1500) or 375 mm (black WHP1500M), with at least 430 mm of insulated chimney left visible
  • Align the roof and ceiling lead-through holes to the actual top flue collar, not the center of the rectangular stove footprint
  • Harvia Legend smoke-pipe drawing places the Legend 150 top connection center 180±5 mm from the back edge
  • Non-combustible base, heat shields, roof/ceiling lead-through, combustion air, and local fire-code review required
  • Safety distances apply only with stones placed per the Harvia manual
  • Legend 150 standard safety drawing: 200 mm combustible side clearance, 250 mm rear clearance, 500 mm front clearance, and 1000 mm top clearance.
  • Legend 150 SL uses the through-wall firebox extension; coordinate non-combustible opening details and adjacent-room clearances.
  • SL feeds through the wall: concrete/brick opening min 220 mm wide, min 390 mm high from the floor, wall max 150 mm thick (manual 292 Fig 13). The 200 mm extension leaves ~50 mm of door proud of the thickest allowed wall.