Harvia Legend GreenFlame 240 is a floor-standing heater from Harvia for 353-706 cu ft adjusted sauna rooms. Key planning facts: 15.9 kW output, 440.9 lb stone capacity, and 82.7" minimum finished ceiling guidance, plus T600 chimney path, 4.53 in flue connection, hearth/floor protection, combustion air, and local fire-code review.
3.94 cu ft per sq ft for glass, stone, tile, brick, concrete, or similar cold surfaces
Chimney / install package
Manual wood stove; chimney and hearth package by installer, Wood stove chimney and hearth package by installer
3D model basis
Harvia cage and firebox CAD with a reconstructed GreenFlame door and handle
Quick answers
What is Harvia Legend GreenFlame 240?
Harvia Legend GreenFlame 240 is a floor-standing heater from Harvia with 15.9 kW output and 440.9 lb stone capacity.
What sauna room size fits Harvia Legend GreenFlame 240?
The published adjusted room-volume range is 353-706 cu ft. Add glass, tile, stone, brick, concrete, or log exposure before choosing the final kW row.
What clearances does Harvia Legend GreenFlame 240 need?
Plan 7.87" side clearance, 9.84" rear clearance, 24.8" front clearance, and a 82.7" minimum finished ceiling check before placing benches or glass.
What chimney does Harvia Legend GreenFlame 240 need?
Plan a T600 chimney path with 4.53 in stove connection, the selected WHP chimney parts or AHJ-approved equivalent, lead-through protection, and local fire-code review.
Where should I start with Harvia Legend GreenFlame 240?
Use the 3D designer to validate the room, benches, openings, combustible clearances, chimney lead-through, guard rail, hearth protection, and material schedule before purchase.
Harvia Legend GreenFlame 240 size and clearance table
Variant
Power
Room volume
Dimensions
Rocks
Side/back
Front
Minimum ceiling
Chimney / install
Legend 240 GreenFlameWKLE20GM
15.9 kW
353-706 cu ft
23.6" W x 23.6" D x 32.9" H
440.9 lb
7.87"
24.8"
82.7"
Manual wood stove; chimney and hearth package by installer
Best fit
15.9 kW Harvia heater family for 353-706 cu ft adjusted hot rooms.
Floor-standing layouts where the heater footprint, front clearance, and bench approach are planned before ordering.
440.9 lb stone capacity with chimney, hearth, heat-shield, and combustion-air planning handled before ordering.
Rooms that can meet the 82.7" minimum finished ceiling check for the selected size row.
Floor structure, non-combustible base, stove guard rail, chimney route, and roof lead-through should be resolved with the full room layout.
Designer checks
Size the room by adjusted volume, including the 3.94 cu ft per sq ft for glass, stone, tile, brick, concrete, or similar cold surfaces rule where it applies.
Validate side/back clearance 7.87", front clearance 24.8", and bench setback before finalizing benches.
Check the 82.7" minimum finished ceiling against the room height.
Carry chimney kit/extensions/damper, lead-through, hearth protection, heat shields, ash handling, and local fire-code review into the material schedule.
The 3D preview includes the GreenFlame glass door and handle. Chimney and protection choices remain separate package components.
Floor-standing sizes use their own body height and top clearance.
Model numbers
WKLE20GM
Useful when the store name and manual model number are not identical.
Room volume range
353-706 cu ft
Use adjusted sauna volume after cold surfaces, not just geometric room volume.
Body weight
165.3 lb
Listed body weight before stones; verify shipping weight with the final SKU.
Cold-surface adder
3.94 cu ft per sq ft for glass, stone, tile, brick, concrete, or similar cold surfaces
The calculator applies the brand-family coefficient before selecting a heater size.
Minimum finished ceiling
82.7"
Computed from body height, floor clearance, top clearance, and the manual minimum room height.
Maximum room height
Not listed for these sizes
Verify with the selected manual when designing unusually tall rooms.
Electrical/control
Wood-burning; no electric heater circuit; Manual wood stove; chimney and hearth package by installer
Use the selected kW row and SKU when matching breakers, phases, relays, and controller packages.
Critical differences
Go-to wood stove family for SaunaDesignPro wood-burning sauna plans T600 chimney required; Harvia manuals list 4.53 in connection opening and 4.34 in minimum flue inner diameter
9 more notes shown below.
Fuel / standard
Wood
Flue class / diameter
T600; 4.53 in connection; 4.34 in min pipe ID
Connection locations: Verify.
WHP chimney clearance
3.94 in insulated chimney to combustibles; 19.69 in single-wall pipe to walls (stainless; 14.77 in with the black WHP1500M connector)
The insulated chimney runs 8.66 in outside diameter over the 4.53 in smoke pipe. Keep at least 16.93 in of insulated chimney visible in the room. Lead-through insulation must be class A or long-term rated at 1382°F or more (Harvia ZSH-200 in the kit).
WHP chimney scope
Vertical roof-pass installs only; standalone outdoor sauna buildings per Harvia support (2026)
For an indoor or residential build, the installer specifies a listed North American chimney path (e.g. UL 103 HT Class A via a 4.5" to 6" adapter) with AHJ sign-off instead of the WHP kit. Harvia 4.53 in smoke pipes and WHP chimneys fit all Harvia wood-heated sauna stoves except the Harvia 50, plus the Harvia 10 iron stove.
WHP chimney limits
16.40 ft max chimney elements; 6.56 ft max freestanding element; 9.84 ft max indoor lateral-support spacing
Go-to wood stove family for SaunaDesignPro wood-burning sauna plans
T600 chimney required; Harvia manuals list 4.53 in connection opening and 4.34 in minimum flue inner diameter
Use Harvia WHP steel chimney kit/extensions/damper or an AHJ-approved equivalent specified by the installer
Harvia WHP steel chimney installs vertically through the roof only, and Harvia support (2026) specifies it for standalone outdoor sauna buildings - indoor or residential builds need an installer-specified listed chimney path (e.g. UL 103 HT Class A)
Harvia WHP steel chimney manual lists 3.94 in minimum clearance from combustibles to the insulated outer casing; the non-insulated connecting pipe needs 19.69 in (stainless WHP1500) or 14.77 in (black WHP1500M), with at least 16.93 in of insulated chimney left visible
Align the roof and ceiling lead-through holes to the actual top flue collar, not the center of the rectangular stove footprint
Harvia Legend smoke-pipe drawing places the Legend 150 top connection center 7.09±0.20 in from the back edge
Non-combustible base, heat shields, roof/ceiling lead-through, combustion air, and local fire-code review required
Safety distances apply only with stones placed per the Harvia manual
GreenFlame 240 manual lists an 82.68 in minimum sauna height and a separate GreenFlame firing/load table.
GreenFlame 240 dimensions and clearances follow its manual. The preview retains Harvia’s common cage and firebox geometry, with the GreenFlame door and handle reconstructed from manufacturer photographs.