Harvia Virta is a floor-standing heater from Harvia with 6-9 kW output and 110-154 lbs stone capacity.
Harvia sauna heater specs
Use this manual-checked commercial grade Harvia Virta HL60E-HL90E US non-Combi page to compare 6-9 kW sizing, 2 in US clearances, Fenix/Xenio controls, 110 lb stones, and the rebuilt CAD-backed 3D room planner.
Harvia Virta is a floor-standing heater from Harvia for 177-494 cu ft adjusted sauna rooms. Key planning facts: 6-9 kW output, 110-154 lbs stone capacity, and 76.2" minimum finished ceiling guidance, and controller guidance: Fenix FX30, Xenio CX30 / Fenix FX45 / Xenio CX45 (required for 240V 1PH), Fenix FX30 / Xenio CX30 (208V 3PH only).
Design with Harvia Virta Buy in North America at Sauna Marketplace
Harvia Virta is a floor-standing heater from Harvia with 6-9 kW output and 110-154 lbs stone capacity.
The published adjusted room-volume range is 177-494 cu ft. Add glass, tile, stone, brick, concrete, or log exposure before choosing the final kW row.
Plan 2.00" side/back clearance, 2.00" front clearance, and a 76.2" minimum finished ceiling check before placing benches or glass.
Current controller guidance: Fenix FX30, Xenio CX30 / Fenix FX45 / Xenio CX45 (required for 240V 1PH), Fenix FX30 / Xenio CX30 (208V 3PH only). Match the controller, relay or power unit, and voltage to the selected kW row before ordering.
Use the 3D designer to validate the room, benches, openings, clearances, and material schedule, then use Sauna Marketplace for the current package and buying path.
| Variant | Power | Room volume | Dimensions | Rocks | Side/back | Front | Minimum ceiling | Controller |
|---|---|---|---|---|---|---|---|---|
| HL60EHL60E / US HL6U1UL family | 6 kW | 177-297 cu ft | 16.2" W x 16.2" D x 32.9" H | 110 lb | 2.00" | 2.00" | 76.2" | Fenix FX30, Xenio CX30 |
| HL80EHL80E / US HL8U1UL family | 8 kW | 177-431 cu ft | 16.2" W x 13.3" D x 32.9" H | 110 lb | 2.00" | 2.00" | 76.2" | Fenix FX45 / Xenio CX45 (required for 240V 1PH), Fenix FX30 / Xenio CX30 (208V 3PH only) |
| HL90EHL90E / US HL9U1UL family | 9 kW | 283-494 cu ft | 16.2" W x 13.3" D x 32.9" H | 110 lb | 2.00" | 2.00" | 76.2" | Fenix FX45 / Xenio CX45 (required for 240V 1PH), Fenix FX30 / Xenio CX30 (208V 3PH only) |
Harvia Virta installation and use manual
source: Harvia Virta HL installation manual, safety drawing, and CAD archive (HL_FISVENDERUETES_ZCU-850_310723_web.pdf; 3743 and 3739 official SAT assets rebuilt through Blender; current Harvia US HL60E, HL80E, HL90E, and HL110E pages checked for sizing, stones, clearances, and body depth; checked June 11, 2026)
Floor-standing
Floor-standing sizes use their own body height and top clearance.
HL60E / US HL6U1UL family / HL80E / US HL8U1UL family / HL90E / US HL9U1UL family
Useful when the store name and manual model number are not identical.
177-494 cu ft
Use adjusted sauna volume after cold surfaces, not just geometric room volume.
3.94 cu ft per sq ft (1.2 m3 per 1 m2) for glass, stone, tile, brick, concrete, or similar cold surfaces
The calculator applies the brand-family coefficient before selecting a heater size.
76.2"
Computed from body height, floor clearance, top clearance, and the manual minimum room height.
Not listed for these sizes
Verify with the selected manual when designing unusually tall rooms.
240V 1PH (U1), 208V 3PH (U3); Fenix FX30, Xenio CX30 / 240V 1PH (U1), 208V 3PH (U3); Fenix FX45 / Xenio CX45 (required for 240V 1PH), Fenix FX30 / Xenio CX30 (208V 3PH only)
Use the selected kW row and SKU when matching breakers, phases, relays, and controller packages.
Harvia Virta is listed as commercial grade in SaunaDesignPro. This Virta page is scoped to the US non-Combi HL60E, HL80E, and HL90E family up to 9 kW; HL60E uses the deeper 3739 body, HL80E/HL90E use the smaller 3743 body, and HL110E plus Virta Combi use separate planning checks.
3 more notes shown below.
HL60E / HL80E / HL90E; non-Combi; up to 9 kW
The Marketplace embed and SEO page intentionally exclude Virta Combi steamer packages and the deeper HL110E body.
2" front / side / back on current Harvia US HL60E-HL90E pages
The local manual/safety sheet also lists 1.18" around the heater and 43.3" to ceiling; use the stricter listing/AHJ value where values conflict.
Wall-distance dependent sensor location
The Virta sensor sheet distinguishes 30-150 mm wall-distance installs from >150 mm installs where the sensor moves to the ceiling. Keep supply airflow from cooling the sensor.
CAD-backed size-specific Virta non-Combi GLBs
The HL80E and HL90E previews use the smaller polished 3743 body, while HL60E uses the deeper 3739 body. Planner dimensions, clearances, and sizing remain row-specific. Virta Combi steam components and the HL110E row stay excluded from this page.