Use this manual-checked commercial grade Harvia Club product page to compare the kW range, adjusted room volume, clearances, controller package, rocks, and buying path before you open the sauna in the designer.

Harvia Club is a floor-standing heater from Harvia for 390-1000 cu ft adjusted sauna rooms. Key planning facts: 10-15 kW output, 132 lbs stone capacity, and 79.5" minimum finished ceiling guidance, and controller guidance: Harvia Xenio or Fenix external control, where required.

Design with Harvia Club Buy in North America at Sauna Marketplace

Power
10-15 kW
Grade
Commercial grade
Rated room volume
390-1000 cu ft
Mounting
Floor-standing
Rock capacity
132 lb
Dimensions
19.9" W x 16.9" D x 27.5" H
Side/rear clearance
5.00"-6.00"
Front clearance
5.00"-6.00"
Top to ceiling clearance
52"
Minimum finished ceiling
79.5"
Cold-surface rule
3.94 cu ft per sq ft (1.2 m3 per 1 m2) for glass, stone, tile, brick, concrete, or similar cold surfaces
Controllers
Wi-Fi Enabled Harvia Xenio Controller for Club, Harvia Xenio or Fenix external control, where required

Quick answers

What is Harvia Club?

Harvia Club is a floor-standing heater from Harvia with 10-15 kW output and 132 lbs stone capacity.

What sauna room size fits Harvia Club?

The published adjusted room-volume range is 390-1000 cu ft. Add glass, tile, stone, brick, concrete, or log exposure before choosing the final kW row.

What clearances does Harvia Club need?

Plan 5.00"-6.00" side/back clearance, 5.00"-6.00" front clearance, and a 79.5" minimum finished ceiling check before placing benches or glass.

Which controller works with Harvia Club?

Current controller guidance: Harvia Xenio or Fenix external control, where required. Match the controller, relay or power unit, and voltage to the selected kW row before ordering.

Where should I start with Harvia Club?

Use the 3D designer to validate the room, benches, openings, clearances, and material schedule, then use Sauna Marketplace for the current package and buying path.

Harvia Club size and clearance table

Variant Power Room volume Dimensions Rocks Side/back Front Minimum ceiling Controller
K10GK10G 10 kW 390-600 cu ft 19.9" W x 16.9" D x 27.5" H 132 lb 5.00" 5.00" 79.5" Harvia Xenio or Fenix external control, where required
K12.5GK12.5G 12.5 kW 500-750 cu ft 19.9" W x 16.9" D x 27.5" H 132 lb 6.00" 6.00" 79.5" Harvia Xenio or Fenix external control, where required
K15GK15G 15 kW 630-1000 cu ft 19.9" W x 16.9" D x 27.5" H 132 lb 6.00" 6.00" 79.5" Harvia Xenio or Fenix external control, where required

Best fit

  • Harvia Club is flagged as commercial grade for larger residential, spa, or hospitality planning.
  • 10-15 kW Harvia heater family for 390-1000 cu ft adjusted hot rooms.
  • Floor-standing layouts where the heater footprint, front clearance, and bench approach are planned before ordering.
  • 132 lbs stone capacity with Harvia Xenio or Fenix external control, where required controller guidance.
  • Rooms that can meet the 79.5" minimum finished ceiling check for the selected size row.
  • Floor space, service access, guard rail planning, and cold-surface sizing should be checked with the full room layout.

Designer checks

  • Size the room by adjusted volume, including the 3.94 cu ft per sq ft (1.2 m3 per 1 m2) for glass, stone, tile, brick, concrete, or similar cold surfaces rule where it applies.
  • Validate side/back clearance 5.00"-6.00", front clearance 5.00"-6.00", and bench setback before finalizing benches.
  • Check the 79.5" minimum finished ceiling against the room height.
  • Carry the selected Harvia Xenio or Fenix external control, where required package into the material schedule and heater placement notes.

Package notes

  • Harvia Club USA heater body
  • 132 lb; AC3000 Sauna Stones for Harvia Club
  • Installation manual
  • AC3000 Sauna Stones for Harvia Club

Manual-backed facts

Source

Harvia Club (KG) owner’s/operator’s manual (Y05-0890)

source: Harvia Club USA installation/CAD archive (Club USA public designer files; GLB ZIP package saved 2026-05-23; checked May 23, 2026)

Mounting

Floor-standing

Floor-standing sizes use their own body height and top clearance.

Model numbers

K10G / K12.5G / K15G

Useful when the store name and manual model number are not identical.

Room volume range

390-1000 cu ft

Use adjusted sauna volume after cold surfaces, not just geometric room volume.

Cold-surface adder

3.94 cu ft per sq ft (1.2 m3 per 1 m2) for glass, stone, tile, brick, concrete, or similar cold surfaces

The calculator applies the brand-family coefficient before selecting a heater size.

Minimum finished ceiling

79.5"

Computed from body height, floor clearance, top clearance, and the manual minimum room height.

Maximum room height

Not listed for these sizes

Verify with the selected manual when designing unusually tall rooms.

Electrical/control

240V 1PH; some sizes available 208V 3PH; Harvia Xenio or Fenix external control, where required

Use the selected kW row and SKU when matching breakers, phases, relays, and controller packages.

Critical differences

Harvia Club is listed as commercial grade in SaunaDesignPro. Club is a floor-standing commercial-grade Harvia heater family with external control packages by model: Harvia pairs K10G with CX30-class controls and K12.5G/K15G with CX45-class controls.

4 more notes shown below.

  • Harvia Club is listed as commercial grade in SaunaDesignPro.
  • Club is a floor-standing commercial-grade Harvia heater family with external control packages by model: Harvia pairs K10G with CX30-class controls and K12.5G/K15G with CX45-class controls.
  • The US Club KG manual (Y05-0890) lists per-model minimum spacing from walls, the protective fence, and benches: 5 in for the 10 kW K10G and 6 in for the 12.5-15 kW K12.5G/K15G - the planner enforces these per size.
  • Club rooms need 52 in above the heater to the ceiling with a 6 ft 5 in minimum, 7 ft normal, and 8 ft maximum ceiling height per the manual installation figures.
  • The manual requires a wood protective fence around the heater (about 1 in off the heater rim and 26 in tall) and ventilation sized to output: 30 sq in inlet/outlet for 10 kW and 45 sq in for 12.5-15 kW, with the outlet about 6 in below the ceiling.
  • Mount the temperature sensor on the wall above the heater about 6 in from the ceiling; Club KG rows use 132 lb stones and Harvia lists a 194 F maximum temperature setting.

More heater pages